Life

3G3FV MANUAL PDF

procedures for installing and wiring the SYSDRIVE 3G3FV-j-CUE/EF3HV-j-CUE Please read this manual thoroughly and handle and operate the product with. The SYSDRIVE 3G3FV is OMRON’s new special-purpose inverter. It provides the harmony between performance, versatility, and simplicity. Using a unique. Manuals and User Guides for Omron SYSDRIVE 3G3FV. We have 1 Omron SYSDRIVE 3G3FV manual available for free PDF download: User Manual.

Author: Mezuru Mogami
Country: Iran
Language: English (Spanish)
Genre: Love
Published (Last): 10 March 2011
Pages: 181
PDF File Size: 12.33 Mb
ePub File Size: 15.45 Mb
ISBN: 787-5-82334-600-8
Downloads: 84759
Price: Free* [*Free Regsitration Required]
Uploader: Zulkree

Droop Control Function Chapter 5 Basic Operation 3g3cv parameter settings which are used most often are explained below. The setting procedure for these three parameters is as follows. Chapter 6 Advanced Operation When this parameter is set to 3, in contrast to a setting of 0, the deceleration time is automatically prolonged with main axis overvoltage OV easily detected. Doing so may result in electrical shock.

Selecting Auto-tuning Carrier Frequency Chapter 5 Basic Operation Note 1. Chapter 6 Advanced Operation H Torque Reference Settings Set multi-function analog input terminal 16 or frequency reference current input terminal 14 to torque reference.

The magnetic flux from the DC injection braking at startup b can also be brought up quickly. Page Chapter 6 Advanced Operation With this setting, the multi-function input resets faults that have occurred. For models of 15 kW or less both V and V classdo not remove or mount the front cover without first removing the Digital Operator; Chapter 6 Advanced Operation Increase the setting in C if vibration occurs when operating with a light load.

  GS716T MANUAL PDF

The same kind of switching is also possible with control circuit terminals set using the multi-function input parameters 1 to 6 set value: This can be adjusted, however, by set- ting a shorter deceleration time than for the 0 setting, so that the actual deceleration time will also be shorter.

Installation Chapter 2 Installation Mounting Wiring Resets the integral value maunal I Chapter 6 Advanced Operation Common Functions This section summarizes the functions that can be used in common among the various modes, and provides detailed explanations of their operations.

Table Of Contents Select peripheral devices which meet the specifications and wire correctly. Page 28 Chapter 1 Introduction Software Ver. Page There is a heat source nearby.

Torque Limit Function Not doing so may result in electrical shock or fire.

Omron SYSDRIVE 3G3FV Manuals

Do not set both parameters L and L to 0, otherwise the Inverter may be damaged. Should you find any problems with the product, immediately contact your nearest local sales representative.

Options Parameter Lists Displays the input voltage setting display. Motor Constant Parameter Lists Page – If there is noise when the inverter is s Clear the recorded user defaults.

OMRON SYSDRIVE 3G3FV – In Stock, We Buy Sell Repair, Price Quote

Mode Accessible parameters Operation The Quick-start level parameters can be displayed. Setting Function Inverter power-on time. The voltage balance between phases is bad. Chapter 6 Advanced Operation Adjust the slip compensation primary delay time if the motor slip compensation responsiveness is low, or if the speeds are unstable.

  AMRUT LAYA THE STATELESS STATE PDF

Monitor Function Chapter 1 Introduction H Dwell Function By holding the output frequency for a constant time during acceleration and deceleration, acceleration and deceleration can 3gg3fv performed without stepping out even when driving a motor with a large start- up load. Motor noise, however, becomes louder when the motor ,anual operated at a speed higher than the rated speed 60 Hz.

OMRON SYSDRIVE 3G3FV USER MANUAL Pdf Download.

Program Only the parameters specified in A manuzl A can be set or displayed. Tighten the screws to a tightening torque of 0. Replace the faulty component.

Page Chapter 7 Parameter Lists This sections lists all parameters that can be used in the Program and Initialize modes. Option Parameters f Ter- minal 22 is the multi-function analog output common. During base block Motor 2 selected ON: Disabled Runs as set.