Technology

HBM T12 PDF

HBM. A en. 1. Scope of supply. • Digital torque transducer (rotor and stator). • T12 Mounting Instructions. • Quick Start Guide for installing the T T12 CANbus/PROFIBUS. HBM. A en. CANopen interface. The CANbus is connected via male device connector 4 or 5. A maximum of. 32 CAN. The innovative digital torque transducer T12 is an ultra-high precision torque transducer for test benches and industrial use.

Author: Jugar Akinogal
Country: Guinea
Language: English (Spanish)
Genre: Relationship
Published (Last): 21 September 2008
Pages: 208
PDF File Size: 16.46 Mb
ePub File Size: 3.6 Mb
ISBN: 439-3-15802-786-5
Downloads: 75874
Price: Free* [*Free Regsitration Required]
Uploader: Tokora

In the window that opens up, select the CANbus hbj add it. HBMshop See prices, availability and get an instant quote. Choose the matching device from the listed devices here: And that’s when there’s neither rotation or load in the test motor’s shaft. Message 10 of Message 5 of Message 1 of Further help is available from the examples that are installed jbm standard on the desktop when the PMX package is installed and from the online Help for the package.

The non-contacting transducer combines the flexibility of digital signal conditioning with the measurement accuracy of a carrier-frequency amplifier without data or accuracy loss. Me and my colleague ran some more tests with the programs and the results are: Is it applied before everything hhm in the case structure or after all else has been done? Automotive and Embedded Networks.

  CREATIVE VISUALIZATION MEDITATIONS GAWAIN SHAKTI PDF

On second try I used queries. I attached the VIs for both methods. Thanks for your interest in our problem!

Automotive and Embedded Networks

Message 8 of T12 – EU Declaration of Conformity. How is the wait actually applied? Did you ever see the torque spikes with the broadcast method?

The query method had the spikes in the torque value. Anke Thanks for the information. Message 3 of The QuantumX MXB digital pulse and frequency module acquires rotational speed, torque, angle, position, displacement, pulse width modulation precisely.

communicating with an HBM t12 torque transducer – Discussion Forums – National Instruments

They feature an optional rotational speed measuring system with reference pulse that provides information about the absolute rotor position, which is required for analysis purposes. As you can see from the broadcast method. Choose the PMX as device. They cannot be used as the basis for any warranty or liability claims. Could this wait be responsible for the loss of data and if so, is it possible to run the readloop without waits and still get the data phased down to more reasonable rates?

  CINESIOLOGIA APLICADA AO ESPORTE PDF

The following overview is shown, hvm the sensor values are displayed. The delay is needed to sort of slow the measurement down. If I continuously read, it shows properly but when I add delay between reads like msthe speed value freezes to the value of the first package read. Could you post the code? I separately read the values of torque and rot.

Minimal linearity deviation, including hysteresis of 0. T12HP – Dessins technique. What is the purpose of the delay? If we don’t slow the measuring down, for example measurements that last for several hours would result in massive logfiles. Hi Drew, and thanks for the fast response!

T12HP is now available with rotational speed up to Message 9 of We also tried to lower the PDO send rate from the transducer parameters but it’s still to fast to be reasonable and with wait s we get problems.